6. Connecting the s88-BiDiB-Link
Connect the s88-BiDiB-Link via RJ-45 patch cables to the s88 modules
or the BiDiB knots. For the sake of clarity, we recommend to use
different coloured patch cables for different types of bus lines, e.g.
green for the BiDiBus,
blue for the s88 bus.
6.1. Use as a s88 interface
Connecting the s88 bus lines
You can connect a maximum of 512 earth contacts to each of the three
s88 connections, or worded differently:
32 x 16-fold feedback modules or
64 x 8- fold feedback modules.
When connecting s88 feedback modules not providing a RJ-45
connection according to S88-N but only a 6-pole plug connector, you
need an additional adapter S88-A. These are available in different
versions for various mounting situations.
Settings
In order to transfer feedback data from the inverface to the PC in HSI-
88 mode, you have to insert a short circuit jumper on JP3. As long as
the connection is open, data are transferred according to the BiDiB
protocol.
Please note: When using the s88-BiDiB-Link simultaneously as a s88
and a BiDiB interface, you have to choose the BiDiB protocol for the
data transfer (to keep the connection JP3 open).