Example for numbering the S88-4 modules. The numbers behind the arrows correspond to the
setting of the code switch.
The S88-4 module with the address 4 cannot get a lower address, as the addresses 1 to 3 are
used by standard modules. The code switch has to be set to "2" as one standard module is
preceding.
The S88-4 modules with the addresses 5, 6, 10 and 11 are preceded by three standard
modules. The address 7, 8 and 9 are not in use in the shown system, which does not influence
the mode of operation.