User manual
tams elektronik
!
English S88-3
8. Check list for troubleshooting
Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: one or more components are soldered incorrectly.
à In case you have mounted the module from a kit, perform a
visual check (à section 6.) and if necessary, remedy the faults.
Otherwise send in the module for repair.
The central unit, the memory or the interface do not show the
proper status.
Possible cause: The connection(s) between the feedback module and
feedback modules connected in series or the digital device are
interrupted. à Check the connections. When using a ribbon cable,
check as well, if the connecting socket of the ribbon cable is put on
in the right direction.
Possible cause: The connection between the input and the mass
contact is interrupted. à Check the connections.
Page 20