User manual
tams elektronik
English SD-34 | SD-34.2
Name of CVs CV-
no.
Input value
(Default)
Remarks and tips
Decoder address
1 to 63
1 1, 2, 3, ... 63
(1)
NB: In addition, you have to
input the value "0" in CV#9.
Decoder address
(64 to 510)
9 0, 1, 2, 3 ... 7
(0)
Please notice: You have to
input a value in CV#1 as well.
Determining the input values for addresses higher
than 64:
1. Divide the chosen address by 64. Round down
the result to a whole number. Input this value in
CV#9.
2. Multiply the value set for CV#9 multiply by 64.
Subtract this result from the chosen address. Enter
this value in CV#1.
Example: address 415:
1. 415 / 64 = 6,5 à CV#9 = 6
2. 415 – (6 x 64) = 31 à CV#1 = 31
Setting the address with the programming jumper or push-
button
SD-34:
Solder pin for
plugging on the
programming jumper
SD-34.2:
Programming
push-button
Page 24