Problems with switching via the switching input
After passing a permanent magnet in the rails no action is activated.
Possible cause: The reed contact or the Hall sensor has been
mounted incorrectly. Check the connections.
Possible cause: The distance to the magnet is too large or the
magnet is too weak. Alter the position of the magnet (if possible)
or use a stronger one.
Possible cause: The magnet has been mounted incorrectly polarized.
Alter the mounting direction.
Possible cause: The assignment of the function to the switching
input is wrong or the minimum switch-on time is too short. Check
the inputs in CV 62 and 97.
Problems in analogue mode
The decoder does not react in analogue mode.
Possible cause: The analogue mode is switched off. Alter the value
for CV 29.
The decoder does not switch to analogue mode (or switches over
although it is still digitally controlled).
Possible cause: The value in CV 11 is set too high or too low. Alter
the value and check the settings in operation.
Page 50