8.10. Information
Name No. Input values
(Default)
Remarks and tips
Version 7 ---
Read only in DCC format!
Manufacturer 8 --- (62)
Read only in DCC format!
Permitted
modes of
operation
12 --- (37)
Readable in DCC format only!
Defines the permitted modes of
operation for the decoder
FD-R Basic.3:
37 = 1 + 4 + 32
1 = DC | 4 = DCC | 32 = MM
Method for
function
assignment
96 --- (2)
Readable in DCC format only!
Defines the method for
assigning the functions:
2 = Function assignment via
CVs 257 to 512 in the bank
selected by CV 31 = 0 and
CV 32 = 42
with CVs per function
according to RailCommunity
standard RCN227 section 2