Instructions

tams elektronik
FD-R Basic.3 English
8.9. Auxiliary functions
Name No. Input values
(Default)
Remarks and tips
Reset 8 0 ... 255 Any input value restores the
settings in state of delivery.
Decoder lock 15 0 ... 255 (3) Changing the CV values of the
decoder is only possible if the
values in CV 15 and 16 are
identical.
By assigning specific values in
CV 16 the CVs of decoders with
the same address can be
changed separately.
16 0 ... 255 (3)
Application e.g. for vehicles or train formations with several decoders with the same address
(e.g. locomotive, sound, function decoders).
Index for
higher
CV-Pages
31 0 (0)
Adjustable in DCC format only!
Function mapping 0
32 0 (42)
Adjustable in DCC format only!
Function mapping 42
Note: If different values are entered in CV 31 and/or 32 the function mapping for the function
outputs and special functions cannot be changed.
Page 47