English FD-R Basic.3
Setting the Packet Time Out
Name No. Input values
(Default)
Remarks and tips
Packet Time
Out
11 2 … 255
(16)
Time period between the failure
of the digital signal and the
change to the alternative
operation (analogue operation).
Increasing the input value by
"1" extends the time period by
10 ms.
Hint: If the decoder is supplied by a buffer circuit, the locomotive would continue running
unplanned after an emergency stop or a signal stop caused by switching off the track voltage.
To prevent this, you have to set a low value for the Packet Time Out (approx. 16) and switch
off the automatic switch-over to analogue operation in CV 29.