8.3. Effects of the outputs
Assignment of the effects to the outputs
Output No. Input values
(Default)
Remarks and tips
F0f 57 0 ... 255 (0) no effects 0
F0r 58 0 ... 255 (0) Function inverted 1
AUX1 59 0 ... 255 (0)
Flashing on 2
AUX2 60 0 ... 255 (0)
Kicking on 4
Example: Alternating flashing with AUX1 and AUX2:
→ Input value for AUX1: CV 59 = 2 | Input value for AUX2: CV 60 = 3 (1 + 2)
Flashing frequency
Output No. Input values
(Default)
Remarks and tips
F0f 101 1 ... 255 (20) Setting separately for each
output.
1 = highest flashing frequency
255 = lowest flashing frequency
Note: The flashing function must be
switched on for the output.
(CV 57 - 60)
F0r 102 1 ... 255 (20)
AUX1 103 1 ... 255 (20)
AUX2 104 1 ... 255 (20)