Example: Programming for shunting operation
Hint: The connection of the return conductor is not shown.
Outputs
off/on with
function
F0f F0r 1 2
Values
1 2 4 8 1 … 254
CV
name
CV-No.
Set value
CV-No.
Set value
F0 f 257 5 (outputs F0f and AUX1) 260 3 (F3=shunting operation)
F0 r 261 10 (outputs F0r and AUX2) 264 3 (F3=shunting operation)
F3 f 265 12 (outputs AUX1 and AUX2) 268 (255 = off)
F3 r 269 12 (outputs AUX1 and AUX2) 272 (255 = off)
With this programming you achieve the following effects when
changing to shunting operation (here using function F3):
the rear end signal for the active direction of motion will be switched
off and
the three-light head end signal will be switched on on both sides.