User manual
tams elektronik
FD-R Extended English
Special functions for speed level 0
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Switching off
function F0 at
speed level 0
173 0...255
(0)
Determines the functions
(F1 to F8) to switch off the
function F0 at speed level 0.
F1 | F2 1 | 2
F3 | F4 4 | 8
F5 | F6 16 | 32
F7 | F8 64 | 128
Switching on
the outputs at
speed level 0
Switching off
the outputs at
speed level 0
In combination
with CV#173
174
175
0 ... 63
(0)
0 ... 63
(0)
Determines the outputs to be
switched on /off via the
functions defined in CV#173 at
speed level 0.
AUX1 1
AUX2 2
AUX3 4
AUX4 8
AUX5 16
AUX6 32
Inverting the
outputs at
speed level 0.
off = on
on = off
In combination
with CV#173
176 0 ... 63
(0)
Determines the outputs to be
inverted via the functions
defined in CV#173 at speed
level 0.
AUX1 1
AUX2 2
AUX3 4
AUX4 8
AUX5 16
AUX6 32
Page 47