User manual

tams elektronik
English FD-R Extended
Settings for IN3 (servo output or 3. switching input)
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Assignment
servo output
(IN3 )
to the
function keys
167 0 ... 255
(2)
Allowing the servo to be
controlled via POM 0
Activation with F5 1
F6 2
F7 4
F8 8
F9 16
F10 32
F11 64
F12 128
Determining
the operating
mode of IN3
168 0, 1
(0)
IN3 = 3
rd
servo input
or allowing the servo to be
controlled via f-keys 0
Entering the servo folding
square via POM
or via IN1 / IN2 1
Setting the servo The value for the right stop has
to be higher than the value for
the left stop.
left stop 169 40…250 (112)
right stop 170 40…250 (176)
velocity 171 0 … 255 (16) 0 = highest velocity
255 = lowest velocity
Controlling
the servo via
POM / servo
position
172 lowest value
= CV#169
hightest value
= CV#170
The last via POM set value will
be saved and the corresponding
position will be headed for
automatically.
Note: Controlling the servo via POM is not
possible until CV#167 = 0 and CV#168 =
1.
Page 46