User manual

tams elektronik
FD-R Extended English
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Dimming depending
on the speed level
= reduction of the voltage at
the output
"1" = lowest voltage
"255" = maximum voltage
Values are applied to the outputs
determined in CV#114 and starting from a
speed level determined in CV#113 only.
AUX1 123 1...255
(255)
AUX2 124
AUX3 125
AUX4 126
Shunting light
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Shunting light 131 0 ... 255
(0)
for AUX1 1
for AUX2 2
for AUX3 4
for AUX4 8
for AUX5 16
for AUX6 32
to be switched with F3 64
to be switched with F4 128
Example: For AUX2 and AUX 3 shunting light, to be switched with F4:
à input value: 134 (= 2 + 4 + 128)
Kick function
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Kicking time
for direction
"forward"
162
0 ... 255
(32)
0 = short
255 = long
Kicking time
for direction
"backward"
163