Basic settings
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
RailCom
settings
28 0, 1, 2, 3
(3)
0 = no feedback
1 = channel 1 on only
2 = channel 2 on only
3 = channel 1 and 2 on
Configuration
data 1
29 0 ... 64
(14)
Direction "Standard" 0
Reverse direction 1
14 speed levels 0
28 or 128 speed levels 2
Analoge recognition off 0
Analoge recognition on 4
RailCom off 0
RailCom on 8
Linear velocity characteristic 0
Alternat. velocity charact. 16
Basic addresses 0
Not for MM mode: Extended addresses 32
Example: CV#29 = 0. à Direction = "Standard". 14 speed levels. Basic addresses. Automatic
analogue recognition = "off". RailCom = "off".
Example: CV#29 = 46. à Direction = "Standard". 28 or 128 speed levels in DCC-mode. Automatic
analogue recognition = "on". RailCom = "on". Extended addresses.
Tip: If the use of extended addresses is activated in CV#29, the decoder does not react to
signals in Motorola format!
Switching off
at overload
48 --- (64) Determines, at which current
the overload protection
responds. The higher the input
value, the higher is the current
responding at overload
protection.
64 = 1 500 mA
The value of 64 should be
altered as an exception only!
Page 38