User manual

tams elektronik
English FD-R Extended
Settings for a SUSI module
The following CV parameters are relevant only when connecting a SUSI
module controlling the sound depending on the effective motor voltage.
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Starting
voltage
(starting
velocity )
2 0 ... 255
(5)
= The voltage to be output to
the motor at speed level 1.
"0" = 0 Volt
"255" = max. voltage
Acceleration
rate
3 0 ... 255
(4)
= Length of the delay before the
switching to the next higher /
lower speed level when the
locomotive is accelerating /
breaking. The value "255"
corresponds to the max. delay.
Braking rate
4 0 ... 255
(2)
Highest
velocity
5 0 ... 255
(255)
= The voltage to be output to
the motor at the highest / mean
speed level.
"255" = max. voltage
Mean
velocity
6 0 ... 255
(100)
Braking
performance
with d.c.
voltage
27 0, 32, 64, 96
(0)
No braking with d.c. voltage 0
Braking with negative
d.c. voltage 32
Braking with positive
d.c. voltage 64
Tip: It is standard to switch over into analogue mode when applying a d.c. voltage at the
rails. In case that the decoder is run in a layout with a braking route based on applying a d.c.
voltage (e.g. Maerklin**-braking route), the automatic recognition of the analogue mode has
to be switched off (CV#29) to ensure that the locomotive reacts as expected on the braking
route.
The setting of the negative or positive d.c. voltage is related to the right rail, as seen in the
locomotive“s direction of motion.
Page 34