5. Technical specifications
Data format DCC and MM
Feedback log RailCom
Supply voltage 12-24 V digital voltage or
max. 18 V analogue voltage
Current consumption
(without connected loads) max. 40 mA
Max. total current 1 500 mA
Number of function outputs
max. current per output
6
500 mA
Output for servo
max. current for servo output
1
5 mA
Output for loudspeaker
Playback
Impedance
Rated load-carrying capacity
1
mono
> 4 Ohm
> 0.1 Watt
Number of switching inputs 3
Note: One switching input is
for optional use as servo
output, then there are only 2
switching inputs available.
Connection for buffer capacitor
Capacity
Electric strength
1
220 to 1.000 µF
> 35 V
Interface SUSI
Protected to IP 00
Ambient temperature in use 0 ... +60 °C
Ambient temperature in storage -10 ... +80 °C
Comparative humidity allowed max. 85 %
Dimensions without SUSI connector approx. 24 x 14 x 2,5 mm
Weight without cables / SUSI
connector
approx. 2 g