5.7. Settings for the switching inputs
Name No. Input values
(Default)
Remarks and tips
Assignment of the
functions to the
switching inputs
F0 … F7
F0 1
F1 2
F2 4
Switching input 1 105
1 … 255 (0) F3 8
F4 16
Switching input 2 107
1 … 255 (0) F5 32
F6 64
F7 128
Assignment of the
functions to the
switching inputs
F8 … F15
F8 1
F9 2
F10 4
Switching input 1 106
1 … 255 (0) F11 8
F12 16
Switching input 2 108
1 … 255 (0) F13 32
F14 64
F15 128
Minimum switch-
on time of the
switching inputs
= Time period for which the input remains
at least on after it has been connected to
ground.
Increasing the input value by "1" extends
the time period by 0.1 sec.
0 = 0 sec. (off)
255 = 25.5 sec.
Switching input 1 97 0 … 255 (0)
Switching input 2 98 0 … 255 (0)
Example:
The shunting gear (here switched with F3) is to be activated automatically for the duration of the
crossing over a switch road (here 10 seconds).
CV 105 = 8 (assignment of the switching input 1 to F3)
CV 97 = 100 (= 10 seconds)
54 | Configuration variables and registers