User manual
English Locomotive decoders of the series 30 plus
Further settings for driving sound (LD-G-36 plus only)
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Release
threshold at
increase of
motor load
921 0 ... 128
(3)
0 = change of sound at least
increase or decrease of motor
load
128 = no change of sound at
increase or decrease of motor
load
Release
threshold at
decrease of
motor load
922 0 ... 128
(3)
Switching
threshold for
ventilator of
e-locomotives
923 0 ... 255
(128)
0 = immediate reaction towards
changes
128 = ventilator sound /
braking sound switched off
Threshold for
braking sound
924 0 ... 255
(44)
Reaction
to load
changes
925 1 ... 8
(6)
1 = quickest possible reaction
8 = slowest possible reaction
Time of no-
load running
937 1 ... 254
(15)
"0" = immediate return in the
load mode
"255" = no automatic return in
the load mode
Adjusting the exhaust bangs to the
locomotive“s speed level
For operation without clock
generator only!
Maximum of
exhaust bangs
938 50 ... 255
(0)
Minimum of
exhaust bangs
939 50 ... 255
(0)
Page 80