User manual
Locomotive decoders of the series 30 plus English
Coupling function
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Time-out for
coupling
function
96 0 ... 255 (10) = maximum length of time for
the coupling operation (in
seconds) before breaking off.
Function key
F1 to F4
and direction
for input 1
for input 2
97
99
0 ... 255 (0) = defines the function key
releasing the coupling function
and the direction of coupling
backwards 0
forwards 128
F1 1
F2 2
F3 4
F4 8
Function key
F5 to F12
and direction
for input 1
for input 2
Hint: Setting the
direction of travel
in CV##97 and 99
98
100
0 ... 255 (0) F5 1
F6 2
F7 4
F8 8
F9 16
F10 32
F11 64
F12 128
Hint: The switching inputs are released respective to decoder ground. If you want to release
them respective to rail ground, you have to mount a resistor (3,3 kOhm).
Motor voltage
for coupling
function
101 1 ... 255 (16) 0 = minimum voltage
(velocity = 0)
255 = maximum voltage
(maximum velocity)
Page 75