User manual
English Locomotive decoders of the series 30 plus
Settings for the servo output (Fortsetzung)
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Assignment
servo output
to the function
keys
167 0 ... 255 (2) Allowing the servo to be
controlled via POM 0
Activation with F5 1
F6 2
F7 4
F8 8
F9 16
F10 32
F11 64
F12 128
Determining
the operating
mode of the
servo output
168 0,1 (0) Allowing the servo to be
controlled via f-keys 0
Entering the servo folding
square via POM 1
Setting the servo The value for the right stop has
to be higher than the value for
the left stop.
left stop
169 40…250 (112)
right stop
170 40…250 (176)
velocity
171 0 … 255 (16) 0 = lowest velocity
255 = highest velocity
Controlling
the servo via
POM / servo
position
172 40…250
(restricted by:
CV#169 à lowest
value and CV#170
à hightest value)
The last via POM set value will
be saved and the corresponding
position will be headed for
automatically.
Note: Controlling the servo via POM is not
possible until CV#167 = 0 and CV#168 =
1.
Page 74