Instructions

tams elektronik
English LD-G-32.2 and LD-W-32.2
Assignment of the outputs to the function keys F0 to F12
Name of CVs /
registers
CV-
no.
Rg-
no.
Input value
(Default)
Remarks and Tips
F0 forward on 33 08 0 ... 3 (1) AUX1 1
F0 backward on 34 09 0 ... 3 (2) AUX2 2
F1 35 10 0 ... 3 (4) AUX3 4
F2 36 11 0 ... 3 (0)
... ...
F12 46 21 0 ... 3 (0)
Factory settings: AUX1 to be switched with F0, switched on at forward motion. AUX2 to be
switched with F0, switched on at backward motion.
Example: AUX2 to be switched with F5 à CV 39 = 2
Example: AUX1 and AUX2 to be switched with F6 à CV 40 = 3 (= 1+2)
Effects of the outputs
Name of CVs /
registers
CV-
no.
Rg-
no.
Input value
(Default)
Remarks and Tips
AUX1 53 26 0 ... 255 (0) Independent of direction 0
AUX2 54 27 0 ... 255 (0) AUX off at backw. motion 1
AUX3 55 28 0 ... 255 (0) AUX off at forward motion 2
Flashing inverted 8
Keying ratio of the flash
lights :
Lighting off 0
16, 32, 48, 64, 80, 96, 112
Regular flashing 128
144, 160, 176, 192, 208, 224
Permanent light 240
Example: Regular flashing at AUX1 and lighting off at forward motion
à CV 53 = 130 (= 128 + 2)
Tip: The keying ratio for the flash lights determines the phase length of the on-/off states of
the lighting.
Page 38