Instructions

tams elektronik
LD-G-32.2 and LD-W-32.2 English
6.3. Using decoders with interface connectors
Many recent locomotives with d.c. motor are equipped ex works with an
interface socket. Using a decoder with a suitable connector saves
separating the connections and soldering works at the locomotive.
Possible versions:
Description Number of poles MOROP standard
6 pole 6 NEM 651
8 pole 8 NEM 652
The interface enables you to connect the decoder to the motor, the rail
current collectors, the lighting and provided the special connector is
designed for it – additional accessories.
When mounting decoders with 6-pole interface connectors according to
NEM 651 or 8-pole interface connectors according to NEM 652, take
care to put the markings on the connector and on the socket on top of
each other.
6.4. Use in locomotives with a.c. motor
The LD-G-32.2 has been designed to control direct current (d.c.)
motors, for that reason it cannot be connected directly to alternating
current (a.c.) motors. You can control a.c. motors with the LD-G-32.2
and benefit of the load control when
mounting a load control adapter between a.c. motor and decoder or
replacing the field coil of the a.c. motor by a permanent magnet.
Page 21