Protection
Protection class Ready-made module (without housing): IP 00
Meaning: No protection against foreign bodies, contact and water.
Ready device (in housing): IP 20
Meaning: Protected against solid foreign bodies with diameter ≥ 12.5 mm and
access with a finger. No protection against water.
Overcurrent protection
(short circuit protection)
Automatic disconnection of the voltage when the set
maximum current is exceeded (2 or 3 A), either
for the affected string or
for all strings
Environment
For use in closed rooms
Ambient temperature during
operation
0 ~ + 30 °C
Permissible relative humidity
during operation
10 ~ 85% (non-condensing)
Ambient temperature during
storage
- 10 ~ + 40 °C
Permissible relative humidity
during storage
10 ~ 85% (non-condensing)
Other features
Dimensions (approx.) Circuit board: 85 x 85 mm
Ready device including housing: 118 x 122 x 47 mm
Weight (approx.) Assembled board (ready-made module): 85 g
Ready device including housing: 395 g