7. Technical data
Interfaces
Booster 2-pole, for connection to track output of booster / central
unit
Short circuit feedback line
2-pole, DCC-compliant ("D" and "E"), optional
Strings 1 to 3 2-pole for connection to tracks of two or three booster
sections
Emergency stop button 2-pole for connection of a push-button ("normally open"
version), optional
Electrical characteristics
Power supply
via the connected booster
Current consumption
max. 60 mA (without consumers)
Output voltage as output voltage of the booster
Output current max. 2 or 3 A per booster section (adjustable)
Configuration
Procedure
Main track programming (POM), DCC compliant
Assignment of turnout
addresses
to the strings | Default values: 100, 101, 102
to the watchdog | Default value: none
Short circuit sensitivity 50...350 ms (adjustable in 50 ms steps)
Default value:100 ms
Reconnection time after a
short circuit
4...9 s (adjustable in 1 s steps)
Default value: 4 s
Behaviour in the event of a
short circuit
Optionally switch off all strings or only the affected string.
Default value: switching off only the affected string
Use of the
Emergency stop button
Also for switching on: yes / no
Default value: yes
Inrush time 300...500 ms (adjustable in 50 ms steps)
Default value: 300 ms
20 | Technical data