Manual
Table Of Contents
tams elektronik
Power-Splitter tams elektronik
5. Operation
5.1. LED displays
A LED is assigned to each of the 3 strings to indicate the various operating states. Note: If
only two booster sections are activated (strings 1 and 2, jumpers inserted on pins 4), the LED
for string 3 remains permanently off.
LED displays for individual strings
Display Meaning
permanently
on
The associated string is switched on.
slow flashing The associated string has been switched off.
fast flashing
There is a short circuit in the associated string.
Note: In this case, the LEDs for the unaffected strings are
permanently on - regardless of whether they have also been
switched off or not (-→ CV setting for behaviour in the event of
a short circuit).
permanently
off
The associated string (string 3) is inactive,
jumper on pins 4 is plugged.
LED displays for all strings
all LEDs
Display Meaning
slow flashing
Change to programming mode
fast flashing
The emergency stop button has been pressed
and all strings have been switched off.
16 | Operation