Manual

tams elektronik
!
tams elektronik Power-Splitter
Function Input value
for CV 7
Setting / Comment
Start
programming
mode
62 To change settings, you must enter a value for CV 7
again within 30 seconds. Otherwise, the programming
mode is automatically terminated.
Reset 8 To reset all settings to the default values (= values at
delivery).
Turnout
addresses
1 Turnout address for string 1. Default value: 100
2 Turnout address for string 2. Default value: 101
3 Turnout address for string 3. Default value: 102
4 Turnout address for watchdog. Default value: none
After you have entered the value 1, 2, 3 or 4 for CV 7, you can assign a
turnout address to one of the strings / the watchdog. To do this, select
a turnout address at your central unit and execute a switching
command for this address.
Short circuit
sensitivity
11 50 ms
12
100 ms = default value
13, 14, … 17
150, 200, 250, 300, 350 ms
Note:
Set the short circuit sensitivity of the Power-Splitter at least 200 ms
lower than that of the booster. Otherwise, the booster may switch off
sooner than the Power-Splitter in the event of a short circuit.
Restart time after
short circuit
24 4 s = Default value
25
5 s
26, 27, … 29
6, 7, 8, 9 s
Emergency stop
button
30
Use of the emergency stop button also for switching
on: no
31 Use of the emergency stop button also for switching
on: yes = Default value
Behaviour in case
of short circuit
40 All strings are switched off.
41
Only the affected string is switched off.
= Default value
Max. duration of
inrush current
("inrush time")
50 300 ms = Default value
51, 52, … 54 350, 400, 450, 500 ms
Settings / configuration | 15