3.2. Connections to the booster sections
Connect the rails of the booster sections to the connections for the strings. Make the
connections to the rails and the disconnections between the booster sections in the same way
as when connecting a booster directly.
Note:
For the connection, use a cable with a cross-section sufficient for the load (recommended
cross-section: > 0,75 mm²). If the cross-section is too small, the overcurrent/short-circuit
shutdown does not work reliably and the cable can become very warm. Fire hazard!
Note:
Make sure that all booster sections have identical polarity! Otherwise, malfunctions may
occur when passing over the separation points (e.g. short circuits, errors during data
transmission).
Note:
If a jumper is plugged onto pins 4.1 and 4.2 of the 2x4-pole pin strip, only strings 1 and 2
(booster sections 1 and 2) are supplied.
Rear side Power-Splitter
Version "Ready device"
Connections | 11