Manual

tams elektronik
!
Power-Splitter tams elektronik
3.1. Connections to the track output of the booster or the central unit
Booster
Connect the booster connector of the Power-Splitter to the track output of the booster or
central unit. You can connect the Power-Splitter to boosters of all types (DCC compliant,
Märklin compatible or other).
Note:
For the connection, use a cable with a cross-section sufficient for the load (recommended
cross-section: > 1.5 mm²). If the cross-section is too small, the overcurrent/short-circuit
shutdown does not work reliably and the cable can become very warm. Fire hazard!
Short circuit feedback
The connection of the short circuit feedback of the Power-Splitter is optional. Connect the
terminals of the Power-Splitter with the terminals D (ground) and E (short circuit feedback) of
the DCC-compliant interface of the booster or the central unit. When doing so, observe the
assignment of the connections.
In combination with boosters or central units that do not have a DCC-compliant booster
interface, the connection of the short circuit feedback of the Power-Splitter is not possible.
Front side Power-Splitter
Version "Ready device"
10 | Connections