1. Getting started
This manual will help you step by step to install and use your booster B-6 safely and properly.
Before  you  start  using  the  booster,  read  through  this  manual  completely,  particularly  the
chapter on safety instructions and the checklist for trouble shooting. You will then know where
to take care and how to prevent mistakes which take a lot of effort to correct.
Keep this manual safely so that you can solve problems in the future. If you pass the booster
on to another person, please pass on the manual with it.
1.1. Contents of the package 
 booster B-6
 power supply unit 
 mains cable (black) with Euro plug (CEE 7/16) and plug for mains cable socket (European
version / C7)
 connection cable (green) with RJ-45 connectors (at least Cat. 5e) 
 1 plug-in connection terminals 2-pole, RM 3.81
 1 plug-in connection terminals 3-pole, RM 3.81
 4 plastic brackets for fixing the booster
1.2. Accessories
Connection cables
Digital control unit via DCC-compliant 
booster interface ("CDE") 
Stranded wire*, recommended cross-section
> 0,25 mm²
Digital control unit 
via BiDiB-interface 
Patch cable (RJ 45)
Note: A patch cable is included in the scope of delivery.
Track
Stranded wire*, recommended cross-section:
0,75 mm² bis 1,5 mm²
(depending on current)
*  The use of  stranded  wire is recommended  for  making the connections.  Stranded  wires
consist of several thin individual wires and are therefore more flexible than rigid wires with the
same copper cross-section.
Distribution of the booster current
In order to utilise the current of 6 A that the B-6 can provide, even with smaller nominal sizes,
a power splitter** can be used. The power splitter distributes the current to 2 to 3 booster
sections with 2 to 3 A each.
Getting started | 5