6. Operation
6.1. Operating and display elements
The Booster B-6 has a button with which you can trigger the following functions:
 switch the track voltage on and off independently of the control unit 
 trigger a reset
 identify the B-6 via BiDiB with the PC control software (BiDiB-Identify)
The display on the front provides you with essential information during programming  and
operation. In  addition, the  RGB LEDs  built into  the housing  change colour,  indicating  the
operating status visibly from a distance. 
6.1.1. Functions of the STOP-GO button
Function
Duration
Display
Colour of the
RGB LEDs
Switch on track voltage press briefly
0.0 | current power
consumption
green
Switch off track voltage press briefly  St. red
Send BiDiB-Identify for 
the B-6 
(→ identification with the 
PC control software)
press and hold until the 
RGB LEDs flash blue. 
To stop sending the signal, press
the button again until the RGB 
LEDs light up green or red again.
blue
flashing
Perform reset 
(restart without resetting 
all settings to the default 
values)
press and hold until the 
blue flashing of the RGB 
LEDs changes to a violet 
rise and fall. 
After the reset, the B-6 
automatically switches back to 
standard operation.
rE
blue
flashing
+ violet 
rising and
falling 
30 | Operation