tams elektronik
!
!
Booster B-6 tams elektronik
Cable cross-sections
For   the   connection  to the  rails,   use   a   cable   with  a  cross-section   sufficient   for   the  load
(recommended cross-section: > 0.75 to 1.5 mm²).
Please note:
If the cross-section is too small, the overcurrent/short-circuit cut-off will not function reliably
and the cable may become very warm. Fire hazard! 
Assignment of the poles of the track connection to the rails
The   assignment   of  the  poles   of   the   siding   to   the   two   rails  (or  the   rail   and   the   centre
conductor) is initially arbitrary. However, this does not apply if you have already connected a
booster to the layout. In this case you must ensure that all booster circuits have identical
polarity! 
Please note: 
If the polarity of the two booster circuits is different, considerable disturbances in the data
transmission and damage to the vehicles, rails and the track outputs of the boosters can
occur when crossing the separation points!