User manual

tams elektronik
Booster B-4 English
7. Settings
The booster B-4 can be set to individual requirements by programming
on main (POM) or by inserting short-circuit terminations (jumpers).
Possible settings Manu-
facturers
settings
Setting
with
jumpers
Track voltage 10 – 24 V, to be set
in 1 V-steps
18 V yes,
16 – 22 V
Autostarting time
after a short circuit
4 – 10 Sek., to be
set in 1 sec.-steps
4 sec. 4 sec.or
10 sec.
Max. track current
(interrupting
current after a short
circuit)
2 – 5 A,
to be set in
1 A-steps
5 A yes
RailCom active or inactive active no
Switching off with a
DCC points
switching command
active or inactive /
assigning the points
address
inactive no
Watchdog active or inactive /
assigning the points
address
inactive no
Limiting value for
short circuit
warning
0,2 – 1 A,
to be set in
0,2 A-steps
0 A
inactive
no
Autostarting time
after 5 short circuits
10 – 100 sec. 60 sec. no
Page 17