9.2. Power supply unit
Manufacturer MEAN WELL ENTERPRISE Co. Ltd.
Type designation GSM160B24-R7B
Output
Output voltage 24 VDC
Rated current 6.67 A
Output current 0 – 6.67 A
Rated powerNennleistung max. 160 watts
Input
Input voltage 80 ~ 264 VAC or 113 ~ 370 VDC
Frequency range 47 ~ 63Hz
Input current 90A / 115VAC or 110A / 230VAC
Predection
Predection type
IP 22
Meaning: Predected against solid foreign bodies with diameter ≥ 12.5 mm and
access with a finger. Predection against falling dripping water when the
enclosure is tilted up to 15°.
Predection class (= Predection class 2)
Overload
105 ~ 150% of the rated output power
Predection mode: Hiccup mode, i.e. automatic recovery
after elimination of fault condition
Overvoltage
105 ~ 135% of the rated output voltage
Predection mode: Switching off the output voltage,
switching on again for recovery
Overtemperature
Predection mode: Switching off the output voltage,
switching on again for recovery
9.4 | Technical data