Instructions

Table Of Contents
tams elektronik
Audio interface Line-out output for connecting active speakers or amplifiers
(2.5 mm stereo jack plug)
Interfaces for external
boosters
Märklin-compatible
DCC compliant
BiDiB
LocoNet
Track outputs Main track
Programming track
Electrical properties
Power supply 24 volts direct current
Note: Only the power supply unit included in the scope of delivery is permitted
as power supply for the mc² including integrated booster!
Maximum total current 6.67 A
Maximum current for
external digital devices
1,200 mA
Note: The specification refers to all digital devices on the CAN, LocoNet,
EasyNet, XpressNet and BiDiB interfaces that are supplied with power via the
respective bus line.
Current consumption
(without consumer)
approx. 150 mA
Integrated Booster
Output voltage 8 to 22 volts digital voltage (regulated)
adjustable in 1 V steps
Maximum output current 1 to 6.5 A
adjustable in 0.5 A steps
Power consumption max. 143 Watt
Digital formats DCC, Motorola, m3
Feedback format RailCom (RailCom cutout can be switched off)
integrated global RailCom detector
Output signal symmetrical
Safety automatic switch-off in case of overload
("short-circuit shutdown")
Short-circuit sensitivity: 10 - 2,000 ms (adjustable)
9.2 | Technical data