Instructions
tams elektronik
English RedBox
Setting the number of s88 modules
Default value Possible settings
0 Value range: 0, 1, 2, 3….52
Setting switching time of solenoid accessory decoders
The setting applies to all solenoid accessory decoders.
Default value Possible settings
minimum switching time:
100 ms
Value range: 0, 50, 100, 150 ... 1000 ms
Hint: When setting a certain minimum switching time, you can switch points by
quickly tapping the function key, although the points need a longer switching time.
maximum switching time:
5.0 s
Value range: 0.1 , 0.2 , 0.3, 0.4 ... 25.5 s
Hint: By setting a certain maximum switching time, you can prevent damages at the
points caused by too long switching times.
Setting interface baud rate (version "V24" only)
Default value Possible settings
57600 Baud
Value range: 1200, 2400, 4800, 9600, 14400, 19200, 38400,
57600
Hints:
When using the serial interface, this value has to be set according to your PC
interface configuration.
The USB interface is 57600 and can’t be changed.
Seite 37