User manual

PZS-3 English
Page 35
The halt at the terminus stations, the stops and the extra halts can be
prolonged by connecting the corresponding input of the module to
earth. Then the train stops at the station, it remains still as long as the
input is connected to earth (at least so long as programmed for the
particular halt). This allows intervention in the automatic shuttle-train
traffic via a switch or an external extra circuit.
If the input which allows you to prolong the halt at the different stops,
is connected to earth while the train is moving, an emergency halt is
released. This prevents an accident when for instance the locomotive
has not accepted the switching impulse for the change of direction.
Technical specifications
Supply voltage for the module 16-18 Volt a.c. voltage
Supply voltage a.c. driving transformer
for the shuttle-train section of it´s own
Current consumption
(without connected loads) approx. 30 mA
Max. current per output 1 A
Protected to IP 00
Ambient temperature in use 0 - + 60 °C
Ambient temperature in storage -10 - + 80 °C
Comparative humidity allowed max. 85 %
Dimensions approx. 73 x 80 mm
Weight approx. 70 g