User manual
tams elektronik
!
FCS modules English
connect this connecting point to the plus pole of the motor and the
other connecting point of the reed contact, together with the enclosed
resistor R10 (10 kW to X8. If the motor runs with this connection, you
have to make the connections the other way round. Connect the
second side of the resistor R10 to the connecting point X3.
Connection of an additional reed contact
If the vehicle is intended to stop abruptly, the connecting point X9 is
not connected and you can skip this section. In order to brake the
vehicle gently, an additional reed contact has to be connected, which
should be mounted as far as possible in the front of the vehicle.
Connect the enclosed reed contact to the connecting points X3 and X9.
Caution: Reed contacts are sensitive to stress. Therfore be
careful when bending the legs in order not to destroy the glass bulb!
Connection of the motor
Connect the enclosed diode 1N4148 to the connections of the motor.
Observe the polarity of the diode. Then connect the minus pole of the
motor to the switch switching the minus pole of the accumulator
batteries and to the connecting point X1. Next connect the collector (C)
of the enclosed transistor BC 327 to the plus pole of the motor, the
basis (B) to the connecting point X7 and the emitter (E) to the resistor
R7. If there is no resistor R7, connect the emitter directly to the plus
pole of the accumulator batteries.
Connection of the dim switch
Connect the connecting points X2, X3 and X5 of the dimming switch to
the connecting points X5, X3 and X2 of the FCS-2.
Next connect the enclosed light depending resistor to the connecting
points X3 and X4 of the Dim switch. The light sensitive resistor has to
be placed that way it is exposed to the ambient lighting when the
housing of the vehicle is closed.
Page 49