11. Check list for troubleshooting
Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: one or more components are soldered incorrectly.
à In case you have mounted the module from a kit, perform a
visual check (à section 6.) and if necessary, remedy the faults.
Otherwise send in the module for repair.
The lamp connected for the functional test of the module does not
light.
Possible cause: one or more components are soldered incorrectly.
(MT-1: e.g. D2, MT-2: e.g. D1). à Alter the mounting direction.
Possible cause: The lamp is defective. à Check the lamp by
connecting it directly to the voltage supply.
MT-2 only: The module does not switch.
Possible cause: The length of time the input is connected to ground
is shorter than the selected time delay. à Reduce the time delay or
lengthen the time the input is connected to ground.