Installation Guide

APPLICATION INSTRUCTIONS FOR
HERITAGE
®
ARCHITECTURAL ASPHALT SHINGLES
DALLAS, TX • FREDERICK, MD • JOPLIN, MO • PHILLIPSBURG, KS
4
TAMKO BUILDING PRODUCTS LLC • P.O. BOX 97 • GALENA, KS 66739-0097 • 800-641-4691 • TAMKO.COM
©2021 TAMKO Building Products LLC. TAMKO, TAMKO logo, Heritage, Moisture Guard, and Elite-Glass Seal are registered trademarks of TAMKO Building Products LLC.
Synthetic Guard and Synthetic Guard Plus are unregistered trademarks of TAMKO Building Products LLC. Rev. 08/23/2021
5. APPLICATION INSTRUCTIONS
STARTER COURSE: A starter course may consist of TAMKO
®
Shingle Starter,
TAMKO
®
10-inch Starter, TAMKO
®
Perforated Starter, or self-sealing 3-tab
shingles. If self-sealing 3-tab shingles are used, remove the exposed tab
portion and install with the factory applied adhesive adjacent to the eaves.
Attach the starter course with approved fasteners along a line parallel to and
1-1/2" to 3" above the eaves edge. The starter course should overhang the
eave edge 1/4" to 3/4" and the rake edge 3/8" to 3/4" if drip edge flashing
is not used along the eaves or rakes. If drip edge flashing is present, install
shingles even with the drip edge or overhang the starter course over the drip
edge up to 3/4". Minimizing overhang at eaves and rakes is recommended
to improve wind resistance of the installed system.
2 CUTS, 5 COURSES, NO-WASTE SHINGLE APPLICATION: Start the first
course with a full-size shingle placed directly over the starter course. Cut
10-3/8" from a full shingle to form a shingle 29" long. Use this to start the
second course (see diagram below). Cut a 23" long shingle to start the
third course. Use the remaining 16-3/8" piece of shingle to start the fourth
course and use the remaining 10-3/8" piece to begin the fifth course.
Continue up the rake in as many rows as necessary using the same formula
as outlined below.
RAKE EDGE
29" 10-3/8"
23" 16-3/8"
29" 10-3/8"
23" 16-3/8"
23"
29"
16-3/8"
Full
10-3/8"
23"
29"
16-3/8"
Full
10-3/8"
repeat
courses
EAVE
Eave flashing or
asphalt saturated felt
Drip edge
Fasteners
located
1-1/2" to 3"
from eave edge
Self-sealing
adhesive
positioned
along eaves
or rake edge
Fasteners
located 1-1/2" to 3"
from rake edge
Starter strips overhang
eaves and rakes
1/4" to 3/8" if no drip edge
flashing is present. If drip
edge flashing is present,
install shingles even with
drip edge or overhang the
drip edge up to 3/4 in.
Underlayment Deck
Eave
Start first strip with 1/2 shingle
removed, then follow with full
strips in order to offset with the
first shingle course.
For maximum wind resistance along rakes, install any
TAMKO starter shingle including sealant or cement shingles
to the underlayment and each other in a 4" width of any
adhesive meeting ASTM D4586, Type 1.
Drip
edge
Rake
4. UNDERLAYMENT
UNDERLAYMENT: An underlayment must be applied over the entire deck
before the installation of TAMKO
®
shingles. Failure to add underlayment can
cause premature failure of the shingles, which is not covered by TAMKO’s
Limited Warranty and Arbitration Agreement.
Products which are acceptable for use as underlayment are:
Asphalt Saturated Felt Underlayments
Any TAMKO
®
non-perforated asphalt saturated organic felt
A non-perforated asphalt saturated organic felt which meets
ASTM D226 or ASTM D4869
Specialty Underlayments
Synthetic Guard
TM
Plus Underlayment or Synthetic Guard
TM
Underlayment
A polymeric underlayment designed for use with
asphalt shingles which meets ASTM D8257
TAMKO
®
Moisture Guard
®
Ice & Rain Underlayment
,
TW Underlayment or TW Metal and Tile Underlayment
(additional ventilation may be required—contact TAMKO’s
Technical Services Department for more information)
A self-adhesive underlayment designed for use with
asphalt shingles which meets ASTM D1970
For Asphalt Saturated Felt Underlayments
Apply the felt when the deck is dry. On roof decks with slopes 4"
per foot and greater apply the felt parallel to the eaves lapping
each course of the felt over the lower course at least 2". Where
ends join, lap the felt 4". If left exposed, the felt may be adversely
affected by moisture and weathering. Laying of the felt and the
shingle application must be done together.
For All Other Specialty Underlayments
On roof decks with slopes 4" per foot and greater, apply
the underlayment parallel to the eaves in accordance with
underlayment application written instructions. The underlayment
should not be left exposed for a longer period of time than is
specified in the underlayment application written instructions.
The final roof covering must be installed before the structure is
exposed to adverse weather conditions, such as wind driven rain,
high wind, hail, ice storms, etc.
In areas where ice builds up along the eaves or a back-up of water from
frozen or clogged gutters is a potential problem, TAMKO
®
Moisture Guard
®
,
TW Metal and Tile Underlayment or TW Underlayment (or any specialty eaves
flashing product) may be applied to eaves, rakes, ridges, valleys, around
chimneys, skylights or dormers to help prevent water damage. Contact
TAMKO’s Technical Services Department for more information.