Instructions / Assembly

Page 8
start-uP & oPEration
Beforestartingthisfanforthersttime,verifythat:
1. All wiring and connections have been made according to this manual and acceptable wiring standards, and that
this manual and all local codes and standards have been followed in this fan’s installation;
2. No tools or construction debris have been left in, on, or around the fan;
3. The fan’s power cord has been plugged into a 120-volt outlet with uninterupted power; and,
4. The area in front of the fan is as unobstructed as possible, with no object closer than 24” to the face of the fan.
Whenrunningthisfanforthersttime,makesuretoobserveitturningon,runningateachofitsspeed
settings, and turning off from both the attic (to observe the fan itself) and the living space (to observe the
Powered AirLock’s doors).
As shown below, there are four buttons on your fan’s control interface:
When the Digital Touch Controller is connected to the fan, and the fan to power, a red LED will illuminate beneath
the Power Indicator shown above. If the Power Indicator is not illuminated, double-check the connections between
the fan and the controller, and between the fan and the power outlet.
Turn on the fan by touching FAN UP or TIMER UP. The Powered AirLock’s doors will open and there will be a 10
second delay before the fan begins to operate. The fan will start at minimum speed. Green LEDs will illuminate to
indicate the speed setting. If the fan was turned on by TIMER UP, the timer will be set to one hour and blue LEDs
will illuminate to indicate the timer setting.
Press or hold FAN UP to increase the speed incrementally until reaching the desired or maximum speed. Press or
hold TIMER UP to increase the time on the timer in one hour increments until the desired time, or the maximum time
of 12 hours, is achieved.
If the fan is already operating at minimum speed, touch FAN DOWN/OFF to turn off the fan; any time remaing
on the timer will be canceled. If the fan is at any higher speed, press or hold FAN DOWN/OFF to incrementally
decrease the speed until reaching the desired speed or turning the fan off.
Press or hold TIMER DOWN/CANCEL to reduce the time on the timer in one hour increments until the desired
time is achieved or the timer is canceled. If the timer is canceled, the fan will remain on at its current speed. If the
timer expires, the fan will turn off.
Whenever the fan is turned off, the Powered AirLock’s doors will close tightly within about 60 seconds.
FAN UP
FAN DOWN
/OFF
TIMER DOWN/
CANCEL
TIMER UP
Power Indicator
Tamarack HV5500G Whole House Fans Installation Manual, P/N HV5500G.1
©Tamarack Technologies, Inc., 2018. All Rights Reserved.