Installation Manual
Side of Pole
Add. 02
Foundation Recommendation Addendum
Note: The suggestions below are recommendations only. It is the installer’s responsibility to
validate foundation parameters prior to installation, as a local geotechnical report may be required
to assess ground conditions. We recommend consulting with a local engineer familiar with local
regulations and build site requirements, including soil conditions, terrain and load criteria (wind,
snow, seismic). All of these parameters may impact foundation requirements.
**On installations in high loading conditions it is recommended to use options U-bolts in place of
the adjustable banks, and a minimum 3” pipe size.
Note: All Tamarack Side of Pole Mounts are engineered for a maximum height of 30’ above grade, if
mounted on a secure structure built for those heights, such as a telephone pole, light post, etc.
Please refer to optional installation instructions for mounting to these structures.
Mounting Pole Guidelines for 6’ Height
Table 1
Part Number Sch- 40 Nominal Pipe Required
Side of Pole Mounts **2” (2 3/8” OD) to 4” (4 ½ OD)
UNI-SP/01 2” – 4”
UNI-SP/01A 2” – 4”
UNI-SP/01XH 2” – 4”
UNI-SP/01XX 2” – 4”
UNI-SP/02 2” – 4”
UNI-SP/02A 2” – 4”
UNI-SP/02X 2” – 4”
UNI-SP/03 2” – 4”
UNI-SP/03W 2” – 4”
Foundation Hole Guidelines
Table 2
Module Area
Max Wind Speed
Min. Hole Diameter
Min. Hole Depth
Min. Pole Depth
2 – 5 Sq. Feet
90 MPH, Exposure C
15”
24”
18”
6 – 10 Sq. Feet
90 MPH, Exposure C
15”
36”
30”
10 – 16 Sq. Feet
90 MPH, Exposure C
15”
36”
30”
17 – 25 Sq. Feet
90 MPH, Exposure C
18”
62”
56”