Installation Sheet

- 11 -
The dark square is the direction
the dipswitch should be set to.
INTAKE
EXHAUST
LOUVER COVER PLATES
DIRECT INTAKE VENT SYSTEM
This T-M50 water heater may be converted to a direct vent (sealed combustion) appliance by
installing an adapter (Part No. TM-DV50) which will bring all required combustible air from
outside the building. When installing the TM-DV50 conversion kit, please follow all instructions
included with the kit.
The T-M50 must be installed in a location where the proper amount of combustible air
will be available to it at all times without obstructions.
If used as a direct vent appliance, the T-M50 requires a 5” combustible air supply pipe.
The intake pipe must be sealed airtight.
Air supply pipe can be made of ABS, PVC, galvanized steel, corrugated aluminum,
corrugated stainless steel or Category III stainless steel.
Change the dipswitch settings to the direct vent system. (See diagram below)
Sidewall venting is recommended for the direct vent system.
Takagi recommends running the exhaust vent and the intake pipe parallel.
TM-DV50 Direct Vent
Conversion Kit
Make sure power to the unit is
turned OFF before changing
the dipswitch settings.