Water Heater Water Heater Brochure
Hot Water 
Return
Gas Supply
Cold 
Water 
Supply
Hot 
Water to 
Fixtures
Expansion Tank
1. Recirculation pump shall be sized for 2-4 gpm per activated heater (4-8 gpm for T-M50)
2. Recirculation pump shall be controlled by an aquastat. The minimum suggested differential should be 10°F
3. The automatic air should be installed at the highest location of the system in accordance with the manufacturer’s instructions.
Multiple Unit with the Multi-Unit Controller
1. Recirculation pump shall be sized for 2-4 gpm per activated heater (4-8 gpm for T-M50)
2. Recirculation pump shall be controlled by an aquastat. The minimum suggested differential should be 10°F
3. The automatic air should be installed at the highest location of the system in accordance with the manufacturer’s instructions.
Hot 
Water to 
Fixtures
Hot Water 
Return
Cold 
Water 
Supply
Expansion Tank
Gas 
Supply
Multiple Units with EASY-LINK
TM
MULTIPLE UNITS
All application diagrams shown are concept drawings only. These diagrams are only to be used as basic guides. It is up to the application designer to properly design the 
plumbing layout and correctly size all components within an application (pumps, piping, storage tanks, water heaters, etc.). All national and local codes must be followed and will 
dictate proper compliance.
38 