Installation Guide
59 Page
Normal Operaon
Owner's Guide
WARNING
DO NOT adjust any other DIP switches except the No. 5 of the lower
bank of DIP switches for the manual pump operation.
Turn off the power supply to the water heater before changing the
DIP switch settings.
Failure to observe these warnings could lead to carbon monoxide
poisoning or death.
Set DIP switch shown in the table below.
Manual pump operation
Lower bank
of
DIP switches
1 2 3 4 5 6 7 8
ON
No. 5 : OFF
DEFAULT
1 2 3 4 5 6 7 8
ON
No. 5 : ON
Lower bank of DIP switches