Installation Guide

34 Page
-Installaon with dedicated return line-
Check valves must be installed on both of the cold water line and return line.
Please refer to the above diagram.
NOTICE
Model 540P Indoor 540P Outdoor
Maximum Pipe length*
(Hot Water supply line and
Dedicated Return line)
Pipe
Diameter
3/4"
(19 mm)
500 ft (152.4 m)
1/2"
(13 mm)
200 ft (61.0 m)
*These are equivalent length that includes head loss for elbows, tees, unions, etc. An additional pump may be
necessary for circulation systems with longer equivalent pipe lengths.
Air vent

Air
separator
S
Check valve
Check valve
Y-Strainer
Cold water inlet
Expansion tank
Gas supply
Ball valves
Unions
Hot water outlet
Cold water inlet
Gas inlet
Pressure
relief valve
This is a concept drawing only.
Return inlet
Installaon
Installaon Manual