Installation Guide

30 Page
-Clearances for rooop terminaons-
3 ft (914 mm) min.
Exhaust gas
Intake air
1 ft
(305 mm) min.
1 ft
(305 mm) min.
Exhaust and/or direct vent sidewall terminations should
be at least 2 ft (610 mm) away from an opposite surface/
wall. Do not place the termination directly in front of an
opening into a building.
Exhaust terminations must be at least 1 ft (305 mm) away from any obstructions.
Exhaust
termination
2 ft (610 mm)
min.
Installaon Manual
Installaon
Please follow all local and national codes in regards to proper termination
clearances. In the absence of such codes, the clearances below can be used as
guidelines. Local codes supersede these guidelines.
WARNING
Exhaust
gas
2 ft (610 mm) min.
Intake air
1 ft
(305 mm) min.
1 ft
(305 mm) min.
1 ft
(305 mm) min.
Anticipated
snow level
Anticipated
snow level