Water Heater Water Heater Brochure
Stepper Motor Water Valves - M50 Models
Making true commercial-grade water heaters involves more than just redesigning our heat exchangers—every internal component
has to measure up to Takagi’s commercial standards. Just like our advanced heat exchangers, the longevity and functionality of
components such as our water valves and flow sensors are also of great importance.
Our commercial-grade water heaters (510 and H3), as well as our commercial water heaters (CT-199 and M50) feature a
bypass and flow adjustment valve, which not only provide the optimal control and precision essential for commercial usage, but
also offer the durability needed to handle tough, high-volume conditions.
Bypass Valve - 510U/C,
CT-199 and H3 Models
Flow Adjustment - 510U/C,
CT-199 and H3 Models
Water Flow
Condensation can build up over time in any heat exchanger, causing damage and premature leaks. Takagi’s commercial
models (M50 series) include condensation reduction features that safeguard against these types of damaging effects.
Better Water Pathway Design
By redesigning and redirecting the flow of water, the temperature of the heat exchanger drum and finned coils stay elevated
above dew point, making it much more difficult for condensation to build.
Fin Pitch
By widening the pitch of the heat exchanger fins, not only do we improve durability by reducing occurrences of blockage,
we also maintain higher temperatures on the upper finned coils. Keeping these coils at elevated temperatures reduces the
likelihood of condensation buildup.
FIN
VALVES AND WATER FLOW
10