User Guide

- 43 -
OPTIONAL ITEMS
1. Temperature remote controller: 9007603005
(TM-RE30)
The temperature remote
controller has two functions. It
allows the output temperature
from the water heater to be
adjusted within the range of
100 °F to 185 °F, and it also
works as a diagnostic tool that
will give a concise error code
whenever there is a problem with the unit. The
temperature options are 100 °F, 105 °F, 110 °F,
115 °F, 120 °F, 125 °F, 130 °F, 135 °F, 140 °F,
145 °F, 150 °F, 155 °F, 160 °F, 165 °F, 170 °F,
175 °F, 180 °F and 185 °F. See the troubleshooting
section for information on
p
ossible error codes.
2. Multi-unit controller: 9007675005
(TM-MC01)
The multi-unit controller can
control a maximum of 10
water heaters, from 15,000
BTU to 3,800,000 BTU. It
also works as a diagnostic
tool that will give a concise
error code whenever there
is a problem with the unit.
Usage of this controller
requires having the
9007603005 (TM-RE30)
remote controller.
3. 5” Backflow preventer and F-F adaptor:
9008202005
There are two functions available for
this adaptor which can be connected
with the water heater and NovaVent
venting line and prevents the
backflow of air through the exhaust
vent. This helps prevent harmful
exhaust gases from entering the
home, as well as helping to prevent
the unit from freezing in areas where
cold air can be blown or drawn into
the exhaust system. Install this adaptor in accordance
with the installation instructions that are packaged
with the adaptor and any applicable codes.
4. Vent cap: 9007677005 (TM-VC50)
The vent cap is for
outdoor installation
with the 910 (T-
M50) water heater.
The cap is
installed on the top
of the unit, instead
of connecting an
exhaust vent pipe. The cap will prevent any
debris that might be in the environment from
entering the unit and causing damage or a fire
hazard, as well as preventing rain or other
weather from entering the unit.
5. Direct-vent conversion kit: 9007669005
(TM-DV50)
This kit can be used to convert the
910 (T-M50) from a conventional
vent system to a direct-vent (or
sealed combustion) system. This is
a CSA tested conversion kit. Install
this conversion kit in accordance
with the manufacturer’s installation
instructions and any applicable
codes.
6. Pipe cover: 9007673005 (TM-PC50)
The pipe cover protects the
plumbing pipes to the 910
(T-M50) from unexpected
adjustments. This pipe cover
is fixed to the bottom of the
water heater, which hides the
plumbing and improves the
visual aspects of the whole
installation for the water heater.
7. Sidewall vent terminator (Hood) and Wall thimble:
They are used when venting out through the wall. These terminations are
special stainless steel vents for gas applications and are UL listed as
Categoly ll, lll and lV. For different wall thickness, there are two ranges of
lengths available. (Refer to the NovaVent brochure for details.) Install these
vent terminations in accordance
with their installation instructions
and any applicable local codes.
Part # Covering wall thickness
9008347005 Wall Thimble 4”-7”
9008348005 Wall Thimble 5”-10”
9008197005 Terminator Hood
Terminator Hood
Wall Thimble