T-M50-ASME-N Installation Manual

- 31 -
*To change the remote controller’s mode from Default Mode to High Temperature Mode,
please follow the procedures below (the remote controller must be installed prior to operating
these procedures):
DO NOT set to 185ºF if you use your water heater in a recirculation system.
This will cause damage to the heater and void the warranty.
1. Turn off power to the remote controller by pressing the “ON/OFF" button.
2. Simultaneously press and hold both the HOT and COLDbuttons for at least five seconds.
And then make sure “1(or “0”) is displayed on remote controller.
“1” is displayed for single units 0” is displayed for Easy-Link / Multi-unit Systems
3. Press the TIMEbutton.
Make sure OFF and F1 are displayed on remote controller.
4. Press the INFObutton. After, make sure OFF” blinks.
5. Press the HOTbutton or the COLDbutton to set display to on”.
6. Simultaneously press both the “BUZZER button and the “INFO button to fix the setting.
7. Make sure display is no longer blinking.
8. Press theON/OFFbutton to finish the setting.
9. Turn on power to the remote controller by pressing the ON/OFF button again.
Blink
Lamp is OFF to indicate that power is off
Blink
Not blinking
Lamp is ON