Product Specifications
Model T-K3-OS
06-021-2010
HT W D WT Volt Amp Connections
20.5” 13.8” 8.5” 40 lbs. 120 0.77 3/4” NPT
Max BTU/h Min BTU/h Energy Factor Min Press Max. Press
190,000 11,000 0.82 5.0” W.C. 10.5” W.C.
190,000 11,000 0.82 8.0” W.C. 14.0” W.C.
Input
NG
LP
Input
GPM Water PSI Coil Cap
0.5 - 7.0* 15 - 150 PSI** ≈0.2 Gallons
Clearances Top Bottom Front Back Sides
Outdoor 36“ 12” 24“ 1” 2”
* Category III Required **Current numbers based on factory testing, 0.4 GPM Required for Continuous Fire After initial Ignition.
tube construction with quick release brass or bronze waterways. Heater(s) will be factory assembled and tested.
The heater(s) shall be controlled by onboard solid state printed circuit board monitoring incoming and outgoing temperatures with factory installed
T-K3-OS:
U
P
C
®
13-3/4"(350mm)
5"(128mm)
8"(203mm)
8"(203mm)1-5/8"(42.5mm)
1/6"(4.5mm)
1-3/8"(35mm)
10"(254mm)
1-3/4"(45mm)1-3/4"(45mm)
1-3/8"(36mm)120V
4-7/8"(124.3mm)GAS
1-7/8"(47mm)
3-1/4"(84mm)COLD
5-1/4"(132.9mm)HOT
20-1/4"(514mm)
21-3/8"(544mm)
1-1/4"(31mm)
1"(26.3mm)
2-3/4"(72mm)COLD
5-3/8"(136.1mm)GAS
3-3/4"(96.5mm)120V
6-1/2"(164.4mm)HOT
9-1/2"(241.3mm)
19-3/8"(492.7mm)